Product Introduction
The diesel generator paralleling cabinet is designed for the parallel operation of multiple diesel generator sets, enabling synchronized closing, balanced load sharing, fault protection, automatic start/stop, and grid‑connection/disconnection control. It facilitates coordinated power supply among several generators, making it suitable for applications such as backup power, off‑grid power stations, commercial and industrial emergency power, data centers, and industrial/mining projects. The system supports synchronous parallel operation at identical frequency and voltage, with equitable distribution of active and reactive loads, thereby enhancing the reliability and capacity of the power supply system. It can also be integrated with a utility‑power transfer switch to enable bidirectional interlocking between the diesel generator and the utility grid.
Core Advantages
Precise Synchronous Control: Automatically performs voltage, frequency, and phase synchronization detection, ensures smooth closing and grid connection, reduces inrush current, and protects the generator set itself.
Intelligent Load Balancing: Active and reactive power are automatically balanced and allocated, preventing any single unit from operating under overload or light-load conditions, thereby extending equipment service life and reducing fuel consumption.
Comprehensive Security Protection: It features multiple protection functions, including overvoltage, undervoltage, overfrequency, underfrequency, overload, reverse power, and short-circuit protection; it also provides automatic fault alarms and automatic disconnection and shutdown to mitigate system risks.
Flexible scaling and adaptation: Supports parallel operation of two or more diesel generators, with the number of units scalable as needed; compatible with diesel generators from different manufacturers and integrable with ATS mains‑transfer switchgear.
Multiple operating modes: Supports manual and automatic modes, enabling failed units to automatically disconnect while the remaining units continue to carry the load, ensuring uninterrupted power supply.
Stable, reliable, and easy to maintain: The cabinet is built with industrial-grade components, featuring a well-organized structure and clear wiring; it supports local operation and offers optional remote monitoring communication interfaces for streamlined O&M management.
Strong scene versatility: It is widely used in emergency and backup power supply projects at factories, mines, hospitals, data centers, construction sites, and overseas commercial and industrial power stations.
Product Specifications
Electrical Parameters | Rated voltage | Three-phase 400 V, auxiliary control AC 220 V / DC 24 V |
Rated frequency | 50Hz | |
Wiring configuration | Three-phase four-wire Y0 | |
Rated current | Optional configuration as needed | |
Compatible unit power | Single unit: 90 kW to 3,000 kW; supports parallel operation of 2 to 16 units. | |
Power factor | 0.8 lag | |
Parallel operation control | Synchronous closing accuracy | Voltage difference ≤ ±1%, frequency difference ≤ ±0.1 Hz, phase difference ≤ 10°—automatic synchronization |
Load distribution accuracy | Both active and reactive power are equally divided, with a deviation of ≤±5%. | |
Reverse Power Protection | The threshold is adjustable between 5% and 20% of the rated power, and the delay is adjustable from 0.5 to 15 seconds. | |
Automatic Peak-Shaving Logic | When the load exceeds 80%, additional units are connected to the grid; when the load falls below 50%, units are automatically disconnected and reduced. | |
Closing method | Fully automatic quasi-synchronization, with support for manual synchronization of the standby unit. | |
Protection function | Electrical protection | Overcurrent, short circuit, overvoltage, undervoltage, overfrequency, underfrequency, reverse power, three-phase imbalance |
Diesel Engine Interlock Protection | High water temperature, low oil pressure, overspeed, charging failure, start-up failure, emergency stop | |
Other protections | Synchronization failure interlock, zero‑power disconnection, overload shedding, and fault‑trip interlock. | |
Control system | Master Control Module | Parallel controller brands available for selection. |
Human-machine interface | 7-inch color touchscreen, displaying voltage, current, power, frequency, coolant temperature, and oil pressure in real time. | |
Communication interface | Modbus-RTU/TCP, supporting remote host‑computer monitoring and SMS alerts. | |
Operating Mode | Four-mode switching: automatic/manual/local/remote | |
Cabinet and Environment | Protection rating | IP30 (indoor standard), outdoor IP54 customizable |
Ambient operating temperature | -10℃ to 40℃; storage -40℃ to 80℃ | |
Relative humidity | ≤95% (no condensation) | |
Altitude requirements | ≤2000m (derating required at high altitudes) |
Keywords:
Qualification Certification
Diesel generator paralleling cabinet
Brand:
Zero Line Technology
Capacity:
90 kW–3000 kW
Location:
Weifang, Shandong
Category:
Related products
Vertical Residential Energy Storage Cabinet (16 kWh / 21 kWh / 32 kWh)
Stackable residential energy storage cabinets (5 kWh / 10 kWh / 16 kWh)
Vertical Residential All-in-One Inverter-Storage System (5.12 kWh / 10.5 kWh / 16 kWh)
Stackable Residential Inverter-Storage All-in-One Unit (5 kWh / 10 kWh / 16 kWh)